enafswur

FlashLink® PDF Multi-Use Data Logger

Model 40202, 40203

  • Unit is designed to be used multiple times
  • Logger is provided pre-programed
  • No software needed to download data
  • Built-in USB connector, no special reading devices required
  • Stops recording after downloading data
  • Automatically creates secure PDF report and CSV file
  • Push-button resets and restarts unit for next use
  • Temperature statistics available on LCD
  • Custom configuring available for logging parameters, alarms, and delayed start
Applications: Produce, Prepared Foods, Pharmaceuticals, Chemicals, Storage Units, Refrigerators

This plug-and-play temperature logger comes pre-programmed and can be reused again and again. After each use, the data is downloaded to a USB enabled device as an encrypted PDF file with a unique identification number for record keeping and traceability. Once data is retrieved, simply reset the unit by pushing and holding both buttons till the data is cleared and a new trip ID is created. This makes it a cost-effective cold chain management and logistics solution for monitoring temperature-sensitive commodities during shipping and/or storage. The FlashLink® PDF Multi-Use Data Logger is ideal for tracking products transported between facilities or as an economical replacement for reusable chart recorders. The logger has the ability to monitor environmental conditions in temperature controlled facilities, such as warehouses, distribution centers, processing, packaging or staging areas.

Factory configured, users do not program this unit. In addition, no software is needed to download data as the logger features onboard software which simply needs a USB enabled device to access the information. Data is reported as a secure, encrypted PDF report which the user must save on their local hard drive. Custom configurations are available from the factory to pre-set logging parameters, such as high/low alarm limits, logging intervals and delayed start.

Models

Models
°F 40202
°C 40203

Specifications

FlashLink® PDF Multi-Use Data Logger
FeatureSpecification
DeltaTrak manufactures products under an ISO 9001:2015 registered quality management system
Measurement Range -40°F to 122°F (-40°C to 50°C)
Temperature Resolution 0.2°F /0.1°C
Accuracy ±1.0°F from -4°F to 113°F; (±0.5°C from -20°C to 45°C)
±2.0°F above 113°F; (±1.0°C above 45°C)
±2.0°F below -4°F; (±1.0°C below -20°C)
Data Capacity 16,112 points
Sample Interval 5 minutes
Data Download Time 30 seconds typical
Factory Programmed Alarm Levels High/low limits over entire temp range
Battery Coin Cell Lithium battery
Dimensions 1.93” x 3.62” x 0.67” (49mm x 92mm x 17mm)
Casing ABS plastic
Weight 1.6 oz. (45.36 grams)
Shock Resistance Withstands 3-foot (1 meter) drop to hard surface
Certification CE Mark, Calibration traceable to NIST, ROHS Compliant, BSS 7061 Compliant
Display LCD, Red LED Alarm
Storage Conditions -4°F to 122°F (-20°C to 50°C) 0% to 95% RH w/o condensation
PDF Standards Complies with ISO19005-1, PDF/A, 21 CFR Part 11
Min. System Requirements PC with current operating system
Adobe Reader
Download Requirements Direct USB connection

Support